Portal Home > All Engineering Calculators
4-Tier Verified Calculation Engine

Engineering Calculation & Preliminary Design Platform

Transparent, mathematically rigorous screening and preliminary sizing tools for substation engineers, electrical EPC contractors, HVAC design consultants, and cleanroom facility planners.

✔ 1. Formula Verified → ⚡ 2. Engineering Screening → 📐 3. Standards Referenced → ⚖ 4. Engineer Review Required
🔍
⚡ Electrical Substation Tier B/C

33kV / 11kV Substation Transformer Capacity & Fault Sizing

Aggregates maximum demand, applies diversity and expansion margins, selects standard IS 2026 kVA commercial ratings, and computes prospective secondary short-circuit fault levels.

⚡ Power Distribution Tier A/C

HT/LT Cable Ampacity & Resistive-Inductive Voltage Drop

Calculates full-load current and 3-phase AC voltage drop in XLPE cables. Checks compliance against internal feeder (≤3%) and final branch (≤5%) design limits per NBC / SP 30.

⚡ Power Factor Tier A/B

APFC Capacitor Bank kVAR Sizing & Surcharge Screening

Computes required reactive compensation to achieve target power factor (0.99), recommends standard 25/50 kVAR modular steps, and estimates indicative Discom low-PF penalty savings.

⚡ Backup Generation Tier B/C

Preliminary Industrial DG Set Generator Capacity Estimator

Sizes diesel generator kVA capacity from base linear and motor loads, accounts for starter inrush (DOL, Star-Delta, Soft Starter, VFD), and selects standard OEM ratings (ISO 8528 framework).

⚡ Grounding Systems Tier A/C

Substation Main Earthing Conductor Strip Sizing Tool

Computes adiabatic short-circuit thermal withstand cross-section for Galvanized Iron, Copper, and Aluminum flats. Selects commercial strip sizes with configurable corrosion allowances.

❄️ HVAC Heat Load Tier B

Preliminary HVAC Cooling Load & Tonnage Screening Estimator

Provides preliminary sensible and latent heat load estimates for offices, server rooms, and healthcare facilities. Computes decoupled base/design loads, exact TR, and circulating CFM.

❄️ Cleanrooms & OTs Tier B/C

Cleanroom Airflow Rate (ACPH) & Modular HEPA Sizing

Calculates total circulating airflow for ISO Class 5–8 cleanrooms and hospital OTs (NABH). Computes modular H14 HEPA filter counts using physically verified manufacturer ratings.

❄️ Ventilation Ductwork Tier A/B

Equal Friction Duct Sizing & Aspect Ratio Checking Engine

Determines circular equivalent diameter, iteratively solves Huebscher’s equation for rectangular width given restricted ceiling height, and checks aerodynamic aspect ratio (AR ≤ 4:1).

❄️ Hydronic Piping Tier A/C

Chilled Water Pipe Hydronic Sizing & Hazen-Williams Head Loss

Calculates chilled water GPM and L/s from chiller tonnage. Selects Schedule 40 NB steel pipe enforcing dual screening criteria (velocity ≤ 8.5 FPS and head loss ≤ 4.0 ft/100ft).

❄️ Fan Engineering Tier B

AHU Fan External Static Pressure (ESP) Screening Estimator

Estimates required fan total static head in Pascals, mmWG, and in.wg by aggregating straight duct friction, dynamic fitting allowances, cooling coils, multi-stage filters, and diffusers.

⚡ Switchgear Panels Tier A/C

HT/LT Busbar Sizing & Short-Circuit Thermal Stress

Sizes aluminium and copper busbars for continuous ampacity and short-circuit thermal withstand. Calculates peak dynamic electrodynamic forces on supports.

⚡ Solar EPC Tier B/C

Commercial Rooftop Solar PV Array & Inverter Sizing

Estimates optimum DC solar capacity (kWp), module quantities, on-grid string inverter rating, monthly generation yields, and annual CO2 offsets.

⚡ Illumination Tier A/B

Indoor Lighting Illumination Lux Level & Lumen Method

Calculates required luminaire quantities using zonal cavity RCR and utilization factors. Verifies maintained working-plane Lux and ECBC LPD compliance.

⚡ Motor Control (MCC) Tier A/B

Industrial Induction Motor Starter & Feeder Protection

Computes motor FLA, coordinates Main/Delta/Star contactors for DOL and Star-Delta, sets overload relay bands, and screens backup MCCB ratings.

⚡ Critical Power Tier B/C

Battery Bank & Online Industrial UPS Sizing Tool

Sizes battery bank Ah capacity with IEEE 485 aging reserves, determines series/parallel string arrangements, and sizes float chargers and UPS kVA.

❄️ Psychrometrics Tier A/B

Psychrometric Mixed Air & Coil Sensible Heat Ratio (SHR)

Determines mixed air dry-bulb and humidity ratio, total cooling coil tonnage (TR / kW), Sensible Heat Ratio, and hourly moisture condensate drain flow.

❄️ Cooling Towers Tier A/C

Evaporative Cooling Tower Water Loss & Makeup Sizing

Calculates condenser water circulating flow (GPM/m³h), thermal range, approach, evaporation rate, drift loss, blowdown, and daily makeup water (kL/day).

❄️ Smoke Control Tier A/C

Staircase & Lift Well Pressurization Fan Sizing

Sizes smoke containment pressurization fans (CFM / CMH) based on closed door crack leakage and open door egress velocity. Verifies handle force (≤ 100 N).

❄️ Cleanroom Airlocks Tier B/C

Cleanroom Air Shower & Dynamic Pass Box Sizing

Calculates high-velocity nozzle airflow (CFM/CMH), exit scrubbing velocity (≥ 20 m/s), chamber air change sweeps per cycle, and blower motor rating.

❄️ Energy Economics Tier B/C

Chiller Plant Lifecycle Operating Cost & Payback

Evaluates annual kWh savings, power bill reductions (₹), simple capital payback, and 10-year net financial returns using AHRI 550/590 4-bin part load profiles.

⚖ Statutory Notice & Engineering Disclaimer (Tier D Integration)

The calculation engines hosted on tools.rsele-hvac.com are intended strictly as preliminary engineering screening and feasibility tools for consulting engineers, MEP contractors, and facility managers. Equipment selections utilize standardized catalog brackets and recognized industrial heuristics. These calculations do not constitute formal stamped engineering designs. Final procurement, electrical safety protection coordination, structural duct reinforcement, hydronic balancing, and statutory utility clearances must be verified by a licensed Chartered Engineer or certified MEP consultant in accordance with local statutory requirements.