Portal Home > Electrical Engineering Tools
Cluster 1: Electrical Infrastructure

Electrical Engineering Calculators & Sizing Tools

Formally verified preliminary design calculators for heavy industrial electrical distribution, 33kV/11kV substations, power factor correction, standby diesel generation, earthing systems, busbars, solar PV, indoor lighting, motor starters, and UPS battery banks.

✔ 1. Formula Verified → ⚡ 2. Engineering Screening → 📐 3. Standards Referenced → ⚖ 4. Engineer Review Required
⚡ Substation EPC Tier B/C

33kV / 11kV Substation Transformer Capacity & Fault Sizing

Aggregates maximum demand, selects standard IS 2026 kVA commercial ratings, and computes prospective secondary short-circuit fault levels.

⚡ Power Distribution Tier A/C

HT/LT Cable Ampacity & Resistive-Inductive Voltage Drop

Calculates full-load current and 3-phase AC voltage drop in XLPE cables. Evaluates compliance against feeder (≤3%) and branch (≤5%) design limits.

⚡ Power Factor Tier A/B

APFC Capacitor Bank kVAR Sizing & Surcharge Screening

Computes required reactive compensation to achieve target power factor (0.99), modular steps, and indicative Discom low-PF penalty savings.

⚡ Backup Generation Tier B/C

Preliminary Industrial DG Set Generator Capacity Estimator

Sizes diesel generator kVA capacity from base linear and motor loads, accounts for starter inrush, and selects standard OEM ratings.

⚡ Grounding Systems Tier A/C

Substation Main Earthing Conductor Strip Sizing Tool

Computes adiabatic short-circuit thermal withstand cross-section for Galvanized Iron, Copper, and Aluminum flats with configurable corrosion allowances.

⚡ Switchgear Panels Tier A/C

HT/LT Busbar Sizing & Short-Circuit Thermal Stress

Dimensions continuous ampacity and short-circuit thermal withstand for Al/Cu flats. Calculates peak dynamic electrodynamic forces on supports.

⚡ Solar EPC Tier B/C

Commercial Rooftop Solar PV Array & Inverter Sizing

Estimates required DC solar capacity (kWp), module quantities, commercial string inverter rating, monthly generation yields, and CO2 offsets.

⚡ Illumination Tier A/B

Indoor Lighting Illumination Lux Level & Lumen Method

Calculates luminaire quantities using zonal cavity RCR and utilization factors. Verifies maintained working-plane Lux and ECBC LPD compliance.

⚡ Motor Control (MCC) Tier A/B

Industrial Induction Motor Starter & Feeder Protection

Computes motor FLA, sizes Main/Delta/Star contactors for DOL and Star-Delta, sets overload relay bands, and screens backup MCCB ratings.

⚡ Critical Power Tier B/C

Battery Bank & Online Industrial UPS Sizing Tool

Calculates battery bank Ah capacity with IEEE 485 aging reserves, determines series/parallel string arrangements, and sizes float chargers and UPS kVA.

⚖ Statutory Notice & Engineering Disclaimer (Tier D)

These calculations provide preliminary engineering screening and feasibility sizing. Final procurement, electrical safety protection coordination, and statutory utility approvals must be verified by a licensed Chartered Engineer.